| Golden Engineering, Inc. | ||||
| HOME |
||||
| Products |
Support |
Contact Us |
Company Info |
International Dealers |
XRS-3T |
||||
| For those customers requiring more precise timing of x-ray pulses, Golden Engineering can supply a modified XRS-3 capable of pulsing within two microseconds after a five volt external trigger pulse is supplied. | ||||
XRS-3T SPECIFICATIONS |
||||
| PHYSICAL DIMENSIONS INCLUDING BATTERY PACK | |
| Length | 17.5 in. (44.5 cm) |
| Width | 5.62 in. (14.2 cm ) |
| Height | 7.5 in. (19 cm) |
| Weight | 14 lbs. ( 6.5 Kg ) |
| X-RAY OUTPUT | |
| X-ray dose per pulse | 2.8 milliroentgens at 30 cm from the front of the unit, +/- 0.5 mR |
| Number of pulses per battery charge | 4000 |
| Maximum pulse rate | 13 pulse per second |
| X-ray source size | 1/8 in. (3 mm) |
| Maximum photon energy | Unknown |
| X-ray pulse width | 50 nanoseconds. (.00000005 seconds) |
| X-ray Beam Angle | 90 degrees |
| ELECTRICAL AND THERMAL CHARACTERISTICS | |
| Battery Voltage | 14.4 volts |
| Battery Type | Nickel Cadmium |
| Battery recharge time | 1 hour |
| Battery Charger | DeWalt 14.4 volt 1 hour charger |
| Temperature range | 32 to 120 degrees F (0 to 50 degrees C) |
| Maximum duty cycle | 100 pulses every 3 minutes (2000 pulses per hr) |
| Warm-up | None required |
| Current Draw | 17 amps at 13 pps |
| Time from Trigger to X-ray Pulse | 2.4 microseconds |
| Capacitor Charge Signal | 5 v; 150 ma |
| Trigger Signal | 5v, TTL |