XRS-3T SPECIFICATIONS
   
PHYSICAL DIMENSIONS INCLUDING BATTERY PACK  
Length 17.5 in. (44.5 cm)
Width 5.62 in. (14.2 cm )
Height 7.5 in. (19 cm)
Weight 14 lbs. ( 6.5 Kg )
X-RAY OUTPUT  
X-ray dose per pulse 2.8 milliroentgens at 30 cm from the front of the unit, +/- 0.5 mR
Number of pulses per battery charge 4000
Maximum pulse rate 13 pulse per second
X-ray source size 1/8 in. (3 mm)
Maximum photon energy Unknown
X-ray pulse width 50 nanoseconds. (.00000005 seconds)
X-ray Beam Angle 90 degrees
ELECTRICAL AND THERMAL CHARACTERISTICS  
Battery Voltage 14.4 volts
Battery Type Nickel Cadmium
Battery recharge time 1 hour
Battery Charger DeWalt 14.4 volt 1 hour charger
Temperature range 32 to 120 degrees F (0 to 50 degrees C)
Maximum duty cycle 100 pulses every 3 minutes (2000 pulses per hr)
Warm-up None required
Current Draw 17 amps at 13 pps
Time from Trigger to X-ray Pulse 2.4 microseconds
Capacitor Charge Signal 5 v; 150 ma
Trigger Signal 5v, TTL